Officea Design & Build

← All articles

Building servicesSpace planning

Office Toilet Requirements in India: How Many WCs, Urinals and Basins You Need

By Gurpreet Singh, Co-Founder8 min read

Short answer

Indian building rules for offices ask for at least 1 WC for every 25 men and 1 for every 15 women, 1 wash basin for every 25 people of each sex, urinals on a sliding scale (4 for 71 to 100 men), 1 drinking water point per 100 people with at least one on each floor, and 1 cleaner's sink per floor. On top of that, the 2021 accessibility guidelines ask for a unisex wheelchair-accessible toilet and an ambulant cubicle in every toilet block.

Office washroom lobby with a long vanity of sensor-tap basins, a backlit mirror, a drinking water point, separate doors for men and women and a wide accessible toilet door
Concept render of an office washroom lobby with an accessible toilet. Illustration, not a completed project.

How many toilets does an office need in India? The minimum comes from the sanitation tables of the National Building Code (NBC) 2016 Part 9 and IS 1172, which cities apply through their building bye-laws: 1 WC per 25 men, 1 WC per 15 women, 1 wash basin per 25 people of each sex, a urinal scale for men, drinking water on every floor and a cleaner's sink per floor. Accessible toilets come on top of these counts, not out of them. This guide gives the full table, two worked examples, the accessibility sizes and the checks to make before you sign a lease.

Which rules apply to office toilets

There is no single "office toilet law". Four sets of rules overlap, and a good layout meets all of them.

  1. Building code and bye-laws. NBC 2016 Part 9 (Plumbing Services) and IS 1172:1993 set the number of sanitary fittings by building type. The Model Building Bye-Laws 2016 published by the Town and Country Planning Organisation repeat these tables (Table 4.9 for shops and commercial offices, Table 4.14 for offices), and state bye-laws follow them. This is what the building plan was approved against.
  2. Accessibility. The Rights of Persons with Disabilities Act, 2016 defines a "public building" to include a private building used as a workplace or for commercial activities. The Harmonised Guidelines and Standards for Universal Accessibility in India 2021 give the sizes and fittings for accessible toilets.
  3. Labour law. The Occupational Safety, Health and Working Conditions Code, 2020 has been in force since 21 November 2025 and replaced the Factories Act, 1948. Its Central Rules (notified 8 May 2026) set toilet numbers for factories, mines, construction sites and similar workplaces in the central sphere. Most private offices come under state rules and the state Shops and Establishments Act, which require clean, separate sanitary facilities. Ask your compliance team which applies to you.
  4. The landlord's fit-out manual. In a Grade A tower the common toilets sit in the building core and were sized for the landlord's design occupancy. The manual decides whether you can add toilets inside your floor, where the wet points are and which fittings you must use.

Office toilet requirements: the ratio table

These are the minimums for office buildings as printed in Table 4.14 of the Model Building Bye-Laws 2016, which follows NBC Part 9. "Or part thereof" means you round up: 26 men need 2 WCs, not 1.

FittingFor menFor women
Water closet (WC)1 for every 25 persons or part thereof1 for every 15 persons or part thereof
Ablution tap (health faucet)1 in each WC1 in each WC
UrinalsNone up to 6 men; 1 for 7 to 20; 2 for 21 to 45; 3 for 46 to 70; 4 for 71 to 100; from 101 to 200 add 3%; over 200 add 2.5%Not applicable
Wash basins1 for every 25 persons or part thereof1 for every 25 persons or part thereof
Drinking water1 for every 100 persons, with at least one on each floor
Cleaner's sinkAt least 1 per floor, preferably in or next to the toilets
Executive rooms and conference hallsA toilet suite (1 WC, 1 wash basin, a shower if used round the clock), shared or separate depending on users

The same table also asks for one water tap with drainage for every 50 persons near the work area, which in an office usually means the pantry.

How to count "persons"

  • Use the people the floor is planned for, not today's headcount. If you are planning 200 seats for growth, size the toilets for 200.
  • Use your real gender mix where you know it. Where it is unknown, the bye-law note for commercial offices allows a 1:1 split. Because women need a WC per 15 and men per 25, the mix changes the answer a lot (see the examples below).
  • Add regular visitors. For shops and commercial offices that receive customers, Table 4.9 counts the average number of people present over one peak hour.
  • Accessible toilets are extra. They are a separate requirement, not a way of meeting the WC count.

Worked examples: 60 and 200 seats

Applying the table to three common cases. Numbers are minimums; round up every fraction.

Fitting60 seats (30 men, 30 women)200 seats (100 men, 100 women)200 seats (140 men, 60 women)
WCs for men246
WCs for women274
Urinals246 (4 + 3% of 40, rounded up)
Wash basins (men / women)2 / 24 / 46 / 3
Drinking water points1 per floor2, and at least 1 per floor2, and at least 1 per floor
Cleaner's sink1 per floor1 per floor1 per floor
Accessible toilets1 unisex wheelchair-accessible toilet per toilet block on each floor, plus 1 ambulant cubicle in the men's and in the women's toilets

Two things stand out. A 200-seat office with an even split needs 11 WCs, and the same office with a 70:30 split needs 10, arranged differently. If the landlord's core toilets were planned for an even split and your team is mostly women, the women's side is where the shortfall shows. For comparison, the labour rules for factories and construction sites ask for 1 urinal per 15 men on the same shift, which would mean 7 urinals for 100 men instead of 4. Offices are not bound by that ratio, but it shows how tight the office minimum is at busy times.

Toilet count by office size (70:30 men to women)

Many offices have more men than women on the floor. This table applies the office ratios to six common sizes at a 70:30 split, including accessible toilets. All numbers are minimums, with every fraction rounded up.

Fitting50 seats (35 M / 15 W)100 seats (70 M / 30 W)150 seats (105 M / 45 W)200 seats (140 M / 60 W)300 seats (210 M / 90 W)500 seats (350 M / 150 W)
WCs for men2356914
WCs for women1234610
Urinals2356811
Wash basins, men2356914
Wash basins, women122346
Drinking water points112235
Cleaner’s sinkAt least 1 on each floor
Accessible (wheelchair) toilet, unisex, at least 2,200 x 2,000 mm11111 per toilet block on each floor1 per toilet block on each floor
Ambulant cubicle (with grab rails on both sides)1 of the men’s WCs and 1 of the women’s WCs in every toilet block

How to read it:

  • Accessible toilets are counted separately. The 50 to 200 seat columns assume one toilet block on one floor. Add one accessible toilet for every extra block or floor. Offices of 300 to 500 seats usually span two floors or need two toilet blocks, because no one should have to travel more than 30 m on the same floor to reach an accessible toilet.
  • Ambulant cubicles are part of the WC count. They are ordinary cubicles built a little larger (900 x 900 mm clear in front of the WC) with an outward-opening door and grab rails, for people who walk with difficulty.
  • Urinals above 100 men follow the percentage rule: add 3% of the men between 101 and 200 and 2.5% of the men above 200, rounded up.
  • Drinking water is 1 per 100 people, but never fewer than one on each floor.

Accessible and all-gender toilets

The Harmonised Guidelines 2021 set out how accessible toilets are sized and fitted. The main numbers for an office fit-out:

  • Where: in public buildings, one unisex accessible toilet in each toilet block on each floor, and one cubicle for people with walking difficulties (an "ambulant" cubicle) in both the men's and women's toilets. Nobody should have to travel more than 30 m on the same floor to reach an accessible toilet.
  • Size: a unisex accessible toilet is at least 2,200 x 2,000 mm inside. A Type A room (side transfer from both sides) is at least 2,200 mm wide and 2,300 mm deep with 1,800 x 1,800 mm clear in front of the WC and basin. A Type B room (transfer from one side) is at least 1,700 x 2,200 mm.
  • Door: at least 900 mm clear, opening outwards, two-way or sliding, with a 600 mm horizontal pull bar on the inside and a lock that works with one hand.
  • WC: seat top 450 to 480 mm above the floor, centreline 460 to 480 mm from the side wall, flush lever on the transfer side no higher than 1,000 mm. Wall-hung WCs give more toe space.
  • Grab bars: 200 to 250 mm above the seat; an L-shaped bar (600 mm horizontal, 700 mm vertical) on the near wall and a fold-up bar on the open side.
  • Basin and accessories: basin rim 750 to 850 mm high with knee space under it; lever or sensor taps; mirror bottom edge no higher than 1,000 mm; soap, towel and dryer controls between 800 and 1,000 mm.
  • Alarm: a red pull cord reachable from the WC and from the floor, with a reset button, linked to a point where someone can respond.
  • Ambulant cubicle: 900 x 900 mm clear in front of the WC, outward-opening door and grab rails on both sides.

The guidelines also encourage all-gender single-user toilets (a WC and basin in one lockable room) in public facilities, which suit staff with caregiving roles, transgender colleagues and anyone who wants privacy. The same guidelines say at least 25% of fixtures in public toilets should be Indian-style; many corporate offices do not follow this, so agree the mix with your landlord and team.

Women's washrooms

  • Plan more WCs per head for women (1 per 15 against 1 per 25 for men), and do not trade them away to fit a bigger pantry.
  • Sanitary napkins and lidded bins. The OSH Central Rules 2026 make napkins at no charge, restocked daily, and lidded disposal bins compulsory in the workplaces they cover. Offices are not named, but most companies now provide both; plan a dispenser position and a bin in every cubicle.
  • Lactation room. The Harmonised Guidelines describe one with comfortable seating, a wash basin, power points for breast pumps and a nappy-changing station. Place it near the women's washroom, not inside it.
  • Safety: good lighting in the approach corridor, doors that cannot be seen into from the work floor, and hooks and shelves in every cubicle.

Fit-out design choices that matter

Check the core against your seat count first

Ask the landlord which occupancy the core toilets were designed for, and compare it with your planned seats. Dense layouts can push a floor beyond what the core was sized for. Adding toilets inside your floor is possible but needs drainage routes, waterproofing, floor traps and landlord approval, and it is far cheaper to know this before you sign. Our floor plan audit checks and the Grade A landlord approval checklist cover this step.

Finishes and fittings

  • Floors: anti-skid tiles that stay non-slippery when wet; walls in glazed tiles or another smooth, impervious finish that is easy to clean.
  • Fittings: a health faucet in every WC (the table asks for one ablution tap per WC), wall-hung WCs for easier cleaning, sensor or lever taps, and dual-flush or low-flow fittings if the building targets water efficiency.
  • Ventilation: mechanical exhaust for every toilet and cubicle, kept at negative pressure to the office. See the office HVAC design guide.
  • Lighting: occupancy sensors in toilets save power without anyone noticing; see the lighting guide.
  • Housekeeping: a cleaner's sink and a small janitor store on every floor, and "cleaning in progress" signs.
  • Drinking water: in the pantry or a corridor, not inside the toilet area.
  • Signage: clear signs for men, women, accessible and all-gender toilets, readable from the work floor.

Cabin toilets

A private toilet for the MD's cabin or a boardroom suite counts as an executive toilet suite. It needs its own wet point, exhaust and waterproofing, and it does not reduce the number of common toilets the floor needs. Our fit-out norms by office type show which offices usually ask for them.

What older guides get wrong

Many toilet tables circulating online were written before 2021. We rechecked the common claims against the current sources:

  • "1 WC per 25 men and 1 per 15 women" is correct for offices, but it is only one line of the table. Guides that stop there leave out urinals, basins, drinking water, cleaner's sinks and accessible toilets.
  • Factory toilet scales are out of date. Tables based on the Factories Act no longer apply: the Act was replaced by the OSH Code from 21 November 2025, and the Central Rules 2026 now set 1 latrine per 25 men and 15 women, 1 urinal per 15 men on a shift, and separate toilets for employees with disabilities and transgender employees.
  • Accessibility is not optional. Pre-2021 guides do not mention the Harmonised Guidelines 2021, so they miss the unisex accessible toilet and the ambulant cubicle in each block.
  • A printing slip to watch: Table 4.14 of the Model Building Bye-Laws 2016 prints "two for 15 persons" for women, while Table 4.9 of the same document says 1 for every 15. Designers normally read it as 1 per 15; confirm with your local authority if it matters for an approval.
  • The 50:50 split is a fallback, not a rule. Use your actual or planned gender mix when you know it.

Office toilet checklist

StageCheckOwner
Before signing the leaseCore toilet count and the occupancy it was designed for; accessible toilet on your floor; landlord rules on adding wet areasAdmin / real estate head
Space planningPlanned seats and gender mix; WC, urinal and basin count from the table; distance to toilets from the far desksDesigner
Detailed designAccessible and ambulant toilet sizes, door widths, grab bars, alarm; exhaust; drainage and waterproofing for any new toiletsDesigner and MEP consultant
FittingsHealth faucets, sensor or lever taps, napkin dispensers, lidded bins, hand dryers or towel dispensers, signageDesigner and client
HandoverWaterproofing test, flow test of every tap and flush, exhaust running, alarm tested, as-built plumbing drawingsContractor and client

The full handover list is in what an office handover checklist should contain.

How a design & build partner helps

Toilet problems usually start with a layout drawn without checking the core, then surface after move-in as queues. At Officea Design & Build, the same team plans seats, checks the core toilets against them, coordinates any new wet areas with the landlord and hands over the test records. Officea works from studios in Delhi (Nehru Place), Gurgaon, Noida and Bangalore, and delivers fit-outs across India.

Evaluating a space? Send us the floor plan for a complimentary floor plan audit, and we will tell you whether the toilets are enough for the seats you plan. Already in an office with queues at lunchtime? Book a complimentary office health audit from Officea REFRESH, which covers cleanliness and hygiene.

Frequently asked questions

How many toilets are required in an office in India?

At least 1 WC for every 25 men and 1 WC for every 15 women, rounded up, under the office sanitation table that NBC 2016 Part 9 and the building bye-laws use. A 100-person office with an even split needs 2 WCs for men and 4 for women, plus urinals, basins and an accessible toilet.

How many urinals does an office need?

None up to 6 men, then 1 for 7 to 20, 2 for 21 to 45, 3 for 46 to 70 and 4 for 71 to 100 men. From 101 to 200 men add 3%, and above 200 add 2.5%.

How many wash basins does an office need?

One wash basin for every 25 men and one for every 25 women, or part thereof. A 200-seat office split evenly needs 4 basins on each side.

Is an accessible toilet compulsory in a private office?

The Rights of Persons with Disabilities Act, 2016 treats workplaces as public buildings, and the Harmonised Guidelines 2021 ask for a unisex wheelchair-accessible toilet in each toilet block on each floor plus an ambulant cubicle in the men's and women's toilets. Check what your building already provides before you plan your floor.

What size should an accessible toilet be?

Under the Harmonised Guidelines 2021, a unisex accessible toilet is at least 2,200 x 2,000 mm inside. A Type A room is at least 2,200 x 2,300 mm and a Type B room at least 1,700 x 2,200 mm, with a door at least 900 mm clear.

How many toilets does a 100-person office need with 70% men?

With 70 men and 30 women, the minimum is 3 WCs and 3 urinals for men, 2 WCs for women, 3 wash basins for men and 2 for women, plus 1 unisex wheelchair-accessible toilet for each toilet block on each floor.

Should the toilet count assume a 50:50 gender split?

Only when the mix is unknown. Use your actual or planned mix, because women need a WC per 15 and men per 25. A 200-seat office needs 11 WCs at an even split and 10 at a 70:30 split, arranged differently.

Disclaimer

This guide is general information, not legal or professional advice. Rules change and vary by state and city. Before you design, build or certify an office, check the current version on the official government websites: your city or state development authority's building bye-laws, the Bureau of Indian Standards for NBC 2016 and IS 1172, the Ministry of Housing and Urban Affairs for the Harmonised Guidelines, and the Ministry of Labour and Employment or your state labour department for workplace rules. Confirm with your landlord and local authority as well.

Sources

Planning an office project?

Officea Design & Build plans, designs and builds corporate offices across India under one contract. See our work or the full list of design and build services, or tell us your city, approximate area and target move-in date below and we'll prepare a costed proposal.

Estimate your fit-out cost

Officea's own 2026 rates by tier. Not a quote — send us your details below for an exact number.

Office fit-out cost per sq ft, 2026 rate card (GST extra). Last updated 11 October 2026.
TierDelhi, Gurgaon, Noida, ChandigarhBangalore, Mumbai, Pune, Hyderabad, Chennai, Goa
Basic₹1,800₹2,000
Medium₹2,200₹2,400
Good₹2,600₹2,900
High end₹4,500₹5,000

Bangalore, Mumbai, Pune, Hyderabad, Chennai and Goa run about 10% above Delhi NCR, rounded to the nearest ₹100. Rates cover civil, MEP, flooring, ceiling and standard finishes. Furniture is included in every Officea quote. See every city and tier side by side in the India office fit-out cost index. Plan workstations, cabins and meeting rooms in the office layout planner. See the city pages for Pune, Hyderabad, Chennai, Chandigarh and Goa.

Fit-out tier
₹1,10,00,000
≈ $115,789 total · ₹2,200 / sq ft (≈ $23.16)

Officea's own 2026 indicative rates per sq ft, covering civil, MEP, furniture and finishes at the stated tier. For early budgeting only — exact pricing is confirmed in a written proposal.

Want the exact number for your office?

Complimentary download

The same cost benchmarks and planning checklist as a PDF you can keep and share with your team.

2026 Office Fit-Out Planning & Cost Guide

  • 2026 city-by-city cost benchmarks
  • What actually moves your cost per square foot
  • A before-you-sign, during-construction and handover checklist